Evaluation of the applicability of pinpoint ion chambers for SRS dosimetric quality assurance

Title
Evaluation of the applicability of pinpoint ion chambers for SRS dosimetric quality assurance
Author(s)
김성규백종근장현수[장현수]김응찬이용희오영기[오영기]
Keywords
SMALL-FIELD DOSIMETRY; PHOTON FIELDS; STEREOTACTIC RADIOTHERAPY; GEL DOSIMETRY; DETECTORS; PERTURBATION; BEAMS; FILM
Issue Date
201506
Publisher
KOREAN PHYSICAL SOC
Citation
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.66, no.11, pp.1771 - 1776
Abstract
The aim of the present study was to evaluate the applicability of a Pinpoint ion chamber for the measurement of the absolute dose for dosimetric quality assurance (QA) under the same conditions as are used for actual stereotactic radiosurgery (SRS). A PTW 31014 Pinpoint chamber with a active volume of 0.015 cm(3) was used to measure the absolute doses of small beams. The PTW 60003 natural diamond detector was used as a reference dosimeter. A custom-made cylindrical acrylic phantom (15 cm diameter, 15 cm long) was produced to obtain measurements, and a noncoplanar arc plan was devised to deliver a prescription dose (15-25 Gy) to 80% of the maximum dose to the target in a single fraction by using the BrainLAB planning system. All irradiations were performed by using a Varian Clinac IX 6 MV equipped with a micro-multileaf-collimators (m3) designed by BrainLAB. The acceptability criterion used was a dose difference of less than 3%. The diameter of the target volume was considered the standard parameter in the present study and was used to divide the cases into two groups, that is, a a parts per thousand currency sign 10 mm target diameter group (10 cases) and a > 10 mm target diameter group (13 cases). For the Pinpoint chamber and target diameters of a parts per thousand currency sign 10 mm, dosimetric uncertainties of > 3% were seen in 4 of the 10 cases, and differences ranged widely from 0.7% to 4.85%. On the other hand, for the Pinpoint chamber and target diameters of > 10 mm all dose differences were less than 1.6%, and the mean discrepancy was 0.81%. A highly significant, but moderate, correlation between dosimetric uncertainties and all target diameters was observed for the Pinpoint chamber (R-2 = 0.483, p 0.001). This result indicates that Pinpoint chambers exhibit a field-size dependency when used for SRS dosimetric QA. Based on the results of the present study, we conclude that the use of a Pinpoint chamber for verification of SRS dosimetric QA is unsuitable for all field sizes, but that it can be used to verify the delivered dose of clinical SRS photon beams given a target diameter of > 10 mm. In addition, the use of Pinpoint chambers should be limited to a field size of 12 mm for SRS dosimetric QA, and cross checking with another type of dosimeter should be performed when Pinpoint chambers are used for SRS dosimetric QA.
URI
http://hdl.handle.net/YU.REPOSITORY/32127http://dx.doi.org/10.3938/jkps.66.1771
ISSN
0374-4884
Appears in Collections:
의과대학 > 방사선종양학교실 > Articles
이과대학 > 물리학과 > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE