Simple Estimation Scheme for Initial Rotor Position and Inductances for Effective MTPA-Operation in Wind-Power Systems using an IPMSM

Title
Simple Estimation Scheme for Initial Rotor Position and Inductances for Effective MTPA-Operation in Wind-Power Systems using an IPMSM
Author(s)
강이규[강이규]정해광[정해광]이교범[이교범]이동춘김장목[김장목]
Keywords
MAGNET SYNCHRONOUS MOTOR; DRIVES; GENERATOR; MACHINE; RANGE
Issue Date
201007
Publisher
KOREAN INST POWER ELECTRONICS
Citation
JOURNAL OF POWER ELECTRONICS, v.10, no.4, pp.396 - 404
Abstract
This paper presents simple schemes used to estimate the initial rotor position and the d- and q-axis inductances for effective Maximum Torque per Ampere (MTPA) operation in a wind-power system using an IPMSM (Interior Permanent Magnet Synchronous Machine). An IPMSM essentially requires an exact coordinate transformation and accurate inductance values to use a reluctance torque caused by the saliency characteristic. In the proposed high-frequency voltage testing method, there is no voltage drop caused by the resistance and the electromotive force. The initial rotor position and the inductance can be measured through an analysis of the stator current without turning the rotor. The experimental results are presented in order to illustrate the feasibility of the proposed method.
URI
http://hdl.handle.net/YU.REPOSITORY/23936
ISSN
1598-2092
Appears in Collections: