Full metadata record

DC FieldValueLanguage
dc.contributor.author강원구ko
dc.contributor.authorHongmei Zhu[Hongmei Zhu]ko
dc.contributor.authorEnqi Wu[Enqi Wu]ko
dc.contributor.authorJianbo Chen[Jianbo Chen]ko
dc.contributor.authorChuvan Men[Chuvan Men]ko
dc.contributor.author장유선[장유선]ko
dc.contributor.author최정갑[최정갑]ko
dc.contributor.author이원재[이원재]ko
dc.contributor.author강종성[강종성]ko
dc.date.accessioned2015-12-16T23:59:38Z-
dc.date.available2015-12-16T23:59:38Z-
dc.date.created2015-11-13-
dc.date.issued201006-
dc.identifier.citationBULLETIN OF THE KOREAN CHEMICAL SOCIETY, v.31, no.6, pp.1496 - 1500-
dc.identifier.issn0253-2964-
dc.identifier.urihttp://hdl.handle.net/YU.REPOSITORY/22342-
dc.identifier.urihttp://dx.doi.org/10.5012/bkcs.2010.31.6.1496-
dc.description.abstractSibutramine enantiomers were separated successfully by capillary zone electrophoresis using substituted cyclodextrins as chiral selectors. The effects of cyclodextrin concentration, pH, voltage, buffer type, and electrolyte concentration on the migration time and resolution of enantiomers were examined. Separation of sibutramine enantiomers on an unmodified fused silica capillary (total length, 54 cm; effective length, 45 cm) was achieved using a mixed buffer of 20 mM phosphate/10 mM citrate containing either 5 mM methyl-beta-cyclodextrin (pH 4.3) or 5 mM carboxymethyl-beta-cyclodextrin (pH 6.5). Samples were injected with a pressure of 50 mbar for 5 s and were detected at a wavelength of 223 nm. The established method showed good precision and accuracy, with intra- and inter-day variations of less than 2.9 and 4.7%, respectively, and recoveries of 95.7 - 103.8%. The stability constants of (R)- and (S)-sibutramine demonstrated that the resolution of sibutramine enantiomers was attributable primarily to the difference in stability constants. When this optimized method was applied to the determination of sibutramine enantiomers in commercial drug formulations, it proved to be economical and convenient, affording sufficient accuracy, precision, and reproducibility as well as sensitivity and selectivity.-
dc.language영어-
dc.publisherKOREAN CHEMICAL SOC-
dc.subjectSTABILITY-CONSTANTS-
dc.subjectINCLUSION COMPLEXES-
dc.subjectBINDING CONSTANTS-
dc.subjectBETA-CYCLODEXTRIN-
dc.subjectHYDROCHLORIDE-
dc.subjectCHROMATOGRAPHY-
dc.subjectENANTIOMERS-
dc.subjectSEPARATION-
dc.titleEnantioseparation and Determination of Sibutramine in Pharmaceutical Formulations by Capillary Electrophoresis-
dc.typeArticle-
dc.identifier.wosid000279126800011-
dc.identifier.scopusid2-s2.0-77953943323-
Appears in Collections:
약학대학 > 약학부 > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE